Multiparametric Quantitative MRI for the Detection of IgA Nephropathy Using Tomoelastography, DWI, and BOLD Imaging.

Abstract:

OBJECTIVES: The aim of this study was to noninvasively evaluate changes in renal stiffness, diffusion, and oxygenation in patients with chronic, advanced stage immunoglobulin A nephropathy (IgAN) by multiparametric magnetic resonance imaging using tomoelastography, diffusion-weighted imaging (DWI), and blood oxygen level-dependent (BOLD) imaging. MATERIALS AND METHODS: In this prospective study, 32 subjects (16 patients with biopsy-proven IgAN and 16 age- and sex-matched healthy controls) underwent multifrequency magnetic resonance elastography with tomoelastography postprocessing at 4 frequencies from 40 to 70 Hz to generate shear wave speed (meter per second) maps reflecting tissue stiffness. In addition, DWI and BOLD imaging were performed to determine the apparent diffusion coefficient in square millimeter per second and T2* relaxation time in milliseconds, respectively. Regions including the entire renal parenchyma of both kidneys were analyzed. Areas under the receiver operating characteristic (AUCs) curve were calculated to test diagnostic performance. Clinical parameters such as estimated glomerular filtration rate and protein-to-creatinine ratio were determined and correlated with imaging findings. RESULTS: Success rates of tomoelastography, DWI, and BOLD imaging regarding both kidneys were 100%, 91%, and 87%, respectively. Shear wave speed was decreased in IgAN (-21%, P < 0.0001), accompanied by lower apparent diffusion coefficient values (-12%, P = 0.004). BOLD imaging was not sensitive to IgAN (P = 0.12). Tomoelastography detected IgAN with higher diagnostic accuracy than DWI (area under the curve = 0.9 vs 0.8) and positively correlated with estimated glomerular filtration rate (r = 0.66, P = 0.006). CONCLUSIONS: Chronic, advanced stage IgAN is associated with renal softening and restricted water diffusion. Tomoelastography is superior to DWI and BOLD imaging in detecting IgAN.

SEEK ID: https://seek.lisym.org/publications/226

PubMed ID: 31261295

Projects: LiSyM Pillar IV: Liver Function Diagnostics (LiSyM-LiFuDi)

Publication type: Not specified

Journal: Invest Radiol

Citation: Invest Radiol. 2019 Oct;54(10):669-674. doi: 10.1097/RLI.0000000000000585.

Date Published: 2nd Jul 2019

Registered Mode: Not specified

Authors: S. T. Lang, J. Guo, A. Bruns, M. Durr, J. Braun, B. Hamm, I. Sack, S. R. Marticorena Garcia

help Submitter
Activity

Views: 1535

Created: 3rd Jul 2020 at 09:11

Last updated: 8th Mar 2024 at 07:44

help Tags

This item has not yet been tagged.

help Attributions

None

Powered by
(v.1.15.2)
Copyright © 2008 - 2024 The University of Manchester and HITS gGmbH